InfoDear customers, due to a price increase by DHL, we are unfortunately forced to increase our transport costs as of 01.10.20233.

Free shipping
Shipping within 24h
30 days money back guarantee
Purchase comfortable on account
Buy direct from the manufacturer
Hotline +49 800 123 454 321

Spare lamp ECO PL 18 W (G23)

€15.95*

Available, delivery time: 2-3 Tage (5-7 Tage bei Versand ins Ausland)

Watt
Product number: 601412
Replacement lamp with G23 base for OTF 8001 / 16001
High-quality replacement lamps for UVC-C pond clarifiers. Standardised lamp base fits all makes. The wavelength of the UV-C radiation is 253.7 nm and kills viruses, bacteria and microorganisms (e.g. floating algae)
By using high-purity quartz glass, 92% of the UV-C radiation generated in the lamp is emitted into the environment. Maximum operating time 8,000 hours (about 1 year), after which the lamp must be replaced. The power loss of UV-C radiation during the service life is approx. 20%.
Watt: 5 W, 7 W, 9 W, 11 W , 18 W (G11), 24 W, 36 W, 55 W

Zubehör

Budget UVC PL 7 Watt
Mode of operation: The UV water clarifiers clarify the water with the help of UV-C radiation. This UV-C radiation kills floating algae, protozoa and bacteria and ensures crystal clear water.  Safety instructions: The UV-C radiation produced by the special lamps is dangerous. Always disconnect the mains plug before cleaning or maintenance work. Directcontact with the skin or eyes can cause damage. Before switching on the unit, make sure that there is water flow in the unit to avoid temperature damage. When used outdoors, these units must be protected from frost in winter. We recommend dismantling the UV-C clarifiers.  ATTENTION: Never operate the unit under water! Connection: The scope of delivery includes stepped hose nozzles that are shortened accordingly depending on the size of the hose used. The swivelling connections allow easy installation. Please make sure that the drain is at the highest point to avoid air bubbles in the housing. Cleaning and maintenance: UV-C lamps have a service life of approx. 8000 operating hours and must be replaced regularly. It is advisable to change the lamps annually (preferably in spring) and to clean the quartz glass at the same time. Switch off the unit and stop the water supply. Now open the lower hose connection and completely empty the housing. Now carefully open the screw cap on the side of the unit. Be careful, the lamp is in the socket!   The ballast unit is maintenance-free.  Scope of delivery: UVC unit, lamp, power supply unit, connections and operating instructions

€46.90*
Budget UVC PL 11 Watt
Mode of operation: The UV water clarifiers clarify the water with the help of UV-C radiation. This UV-C radiation kills floating algae, protozoa and bacteria and ensures crystal clear water.  Safety instructions: The UV-C radiation produced by the special lamps is dangerous. Always disconnect the mains plug before cleaning or maintenance work. Directcontact with the skin or eyes can cause damage. Before switching on the unit, make sure that there is water flow in the unit to avoid temperature damage. When used outdoors, these units must be protected from frost in winter. We recommend dismantling the UV-C clarifiers.  ATTENTION: Never operate the unit under water! Connection: The scope of delivery includes stepped hose nozzles that are shortened accordingly depending on the size of the hose used. The swivelling connections allow easy installation. Please make sure that the drain is at the highest point to avoid air bubbles in the housing. Cleaning and maintenance: UV-C lamps have a service life of approx. 8000 operating hours and must be replaced regularly. It is advisable to change the lamps annually (preferably in spring) and to clean the quartz glass at the same time. Switch off the unit and stop the water supply. Now open the lower hose connection and completely empty the housing. Now carefully open the screw cap on the side of the unit. Be careful, the lamp is in the socket!   The ballast unit is maintenance-free.  Scope of delivery: UVC unit, lamp, power supply unit, connections and operating instructions

€54.90*
Budget UVC PL 18 Watt
Mode of operation: The UV water clarifiers clarify the water with the help of UV-C radiation. This UV-C radiation kills floating algae, protozoa and bacteria and ensures crystal clear water.  Safety instructions: The UV-C radiation produced by the special lamps is dangerous. Always disconnect the mains plug before cleaning or maintenance work. Directcontact with the skin or eyes can cause damage. Before switching on the unit, make sure that water is flowing in the unit to avoid temperature damage. When used outdoors, these units must be protected from frost in winter. We recommend dismantling the UV-C clarifiers.  ATTENTION: Never operate the unit under water! Connection: The scope of delivery includes stepped hose nozzles that are shortened accordingly depending on the size of the hose used. The swivelling connections allow easy installation. Please make sure that the drain is at the highest point to avoid air bubbles in the housing. Cleaning and maintenance: UV-C lamps have a service life of approx. 8000 operating hours and must be replaced regularly. It is advisable to change the lamps annually (preferably in spring) and to clean the quartz glass at the same time. Switch off the unit and stop the water supply. Now open the lower hose connection and empty the housing completely. Now carefully open the screw cap on the side of the unit. Be careful, the lamp is in the socket!   The ballast unit is maintenance-free.  Scope of delivery: UVC unit, lamp, power supply unit, connections and operating instructions

€71.50*
Budget UVC PL 24 Watt
Mode of operation: The UV water clarifiers clarify the water with the help of UV-C radiation. This UV-C radiation kills floating algae, protozoa and bacteria and ensures crystal clear water.  Safety instructions: The UV-C radiation produced by the special lamps is dangerous. Always disconnect the mains plug before cleaning or maintenance work. Directcontact with the skin or eyes can cause damage. Before switching on the unit, make sure that there is water flow in the unit to avoid temperature damage. When used outdoors, these units must be protected from frost in winter. We recommend dismantling the UV-C clarifiers.  ATTENTION: Never operate the unit under water! Connection: The scope of delivery includes stepped hose nozzles that are shortened accordingly depending on the size of the hose used. The swivelling connections allow easy installation. Please make sure that the drain is at the highest point to avoid air bubbles in the housing. Cleaning and maintenance: UV-C lamps have a service life of approx. 8000 operating hours and must be replaced regularly. It is advisable to change the lamps annually (preferably in spring) and to clean the quartz glass at the same time. Switch off the unit and stop the water supply. Now open the lower hose connection and completely empty the housing. Now carefully open the screw cap on the side of the unit. Be careful, the lamp is in the socket!   The ballast unit is maintenance-free.  Scope of delivery: UVC unit, lamp, power supply unit, connections and operating instructions

€78.90*
Budget UVC PL 36 Watt
Mode of operation: The UV water clarifiers clarify the water with the help of UV-C radiation. This UV-C radiation kills floating algae, protozoa and bacteria and ensures crystal clear water.  Safety instructions: The UV-C radiation produced by the special lamps is dangerous. Always disconnect the mains plug before cleaning or maintenance work. Directcontact with the skin or eyes can cause damage. Before switching on the unit, make sure that there is water flow in the unit to avoid temperature damage. When used outdoors, these units must be protected from frost in winter. We recommend disassembling the UV-C clarifiers.  ATTENTION: Never operate the unit under water! Connection: The scope of delivery includes stepped hose nozzles that are shortened accordingly depending on the size of the hose used. The swivelling connections allow easy installation. Please make sure that the drain is at the highest point to avoid air bubbles in the housing. Cleaning and maintenance: UV-C lamps have a service life of approx. 8000 operating hours and must be replaced regularly. It is advisable to change the lamps annually (preferably in spring) and to clean the quartz glass at the same time. Switch off the unit and stop the water supply. Now open the lower hose connection and completely empty the housing. Now carefully open the screw cap on the side of the unit. Be careful, the lamp is in the socket!   The ballast unit is maintenance-free.  Scope of delivery: UVC unit, lamp, power supply unit, connections and operating instructions

€86.50*
Budget Stainless Steel UVC 55 Watt
Budget Stainless Steel UVC 55 Watt High performance UVC with stainless steel housing. The electrolytically polished inside of the housing is highly polished and thus reflects the UVC radiation. This reflection improves or increases the utilisation of the radiation by up to 35 %. Mode of operation: The UV water clarifiers clarify the water with the help of UV-C radiation. This UV-C radiation kills floating algae, protozoa and bacteria and ensures crystal clear water.  Safety instructions: The UV-C radiation produced by the special lamps is dangerous. Always disconnect the mains plug before cleaning or maintenance work. Directcontact with the skin or eyes can cause damage. Before switching on the unit, make sure that there is water flow in the unit to avoid temperature damage. When used outdoors, these units must be protected from frost in winter. We recommend dismantling the UV-C clarifiers.  ATTENTION: Never operate the unit under water! Connection: The scope of delivery includes stepped hose nozzles that are shortened accordingly depending on the size of the hose used. The swivelling connections allow easy installation. Please make sure that the drain is at the highest point to avoid air bubbles in the housing. Cleaning and maintenance: UV-C lamps have a service life of approx. 8000 operating hours and must be replaced regularly. It is advisable to change the lamps annually (preferably in spring) and to clean the quartz glass at the same time. Switch off the unit and stop the water supply. Now open the lower hose connection and completely empty the housing. Now carefully open the screw cap on the side of the unit. Be careful, the lamp is in the socket!   The ballast unit is maintenance-free.  Scope of delivery: UVC unit, lamp, power supply unit, connections and operating instructions

€150.00*